Weber (unit)

From Wikipedia, the free encyclopedia.

In physics, the weber (symbol: Wb) is the SI derived unit of magnetic flux. It is named after the German physicist Wilhelm Eduard Weber (1804 - 1891).

The weber may be defined in terms of Faraday's law, which relates a changing magnetic flux through a loop to the electric field around the loop. A change in flux of one weber per second will induce an emf of one volt.

In SI base units, the dimensions of the weber are kg·m2·s-2·A-1. In derived units, they are volt-seconds (V·s).

The weber is a large unit, equal to 1 T m2 = <math>10^8<math> maxwells.

SI electromagnetism units

edit  (http://wikipedia.cas.ilstu.edu/index.php?title=Template:SI_electromagnetism_units&action=edit)

Name Symbol Dimensions Quantity
ampere (SI base unit) A A Current
coulomb C A·s Electric charge, Quantity of electricity
volt V J/C = kg·m2·s−3·A−1 Potential difference
ohm Ω V/A = kg·m2·s−3·A−2 Resistance, Impedance, Reactance
ohm metre Ω·m kg·m3·s−3·A−2 Resistivity
watt W V·A = kg·m2·s−3 Electrical power
farad F C/V = kg−1·m−2·A2·s4 Capacitance
farad per metre F/m kg−1·m−3·A2·s4 Permittivity
reciprocal farad F−1 kg1·m2·A−2·s−4 Elastance
siemens S Ω−1 = kg−1·m−2·s3·A2 Conductance, Admittance, Susceptance
siemens per metre S/m kg−1·m−3·s3·A2 Conductivity
weber Wb V·s = kg·m2·s−2·A−1 Magnetic flux
tesla T Wb/m2 = kg·s−2·A−1 Magnetic flux density
ampere per metre A/m m−1·A magnetic induction
ampere-turns per weber A/Wb kg−1·m−2·s2·A2 Reluctance
henry H Wb/A = V·s/A = kg·m2·s−2·A−2 Inductance
henry per metre H/m kg·m·s−2·A−2 Permeability
(dimensionless) χ - Magnetic susceptibility